THERMODYNAMIC INVESTIGATIONS OF ZEOTROPIC MIXTURE OF R290, R23 & R14 ON THREE STAGE AUTO REFRIGERATING CASCADE SYSTEM

Abstract

The Zeotropic mixture of environment friendly refrigerants (HC's and HFC's) being the only alternatives for working fluid in low temperature refrigeration system and hence three stage Auto Refrigerating Cascade (ARC) system was studied for the existence using 4 combinations of three component Zeotropic mixture of six different refrigerants. The exergy analysis confirmed the existence of three stage ARC system. The performances of the system like Coefficient of Performance (COP), exergy lost, exergic efficiency, efficiency defect and the evaporating temperature achieved were investigated for different mass fractions in order to verify the effect of mass fraction on them. In accordance with the environmental issues and the process of sustainable development, the three component Zeotropic mixture of R290/R23/R14 with the mass fraction of 0.218:0.346:0.436 was performing better and hence can be suggested as an alternative refrigerant for three stage ARC system operating at very low evaporating temperature in the range of -97°C (176K) at COP of 0.253 and comparatively increased exergic efficiency up to 16.3% (58.5%).

Dates

  • Submission Date2014-01-03
  • Revision Date2014-06-25
  • Acceptance Date2014-07-12
  • Online Date2014-08-03

DOI Reference

10.2298/TSCI140103091S

References

  1. Anand,S., Tyagi,S.K., Exergy analysis and experimental study of a vapour compression refrigeration cycle, Journal of Thermal Analysis and Calorimetry, 110 (2012), pp. 961-971.
  2. Ciro Aprea., Angelo Maiorino., Heat rejection pressure optimization for a carbon dioxide split system: An experimental study, Applied Energy, 86 (2009), pp. 2373-2380.
  3. Cleland,D.J., et.al., Use of hydrocarbons as drop-in Replacements for HCFC-22 in on-farm Milk Cooling Equipment, International Journal of Refrigeration, 32 (2009), pp. 1403-1411.
  4. Dave Sajjan., et.al., Reasons for drop in shell - and - tube Condenser Performance when Replacing R22 with Zeotropic Mixtures. Part 1: Analysis of Experimental Findings, International Journal of Refrigeration, 27 (2004), pp. 552-560.
  5. Dongsoo Jung., et.al., Testing of Propane/Isobutane Mixture in Domestic Refrigerators, International Journal of Refrigeration, 23 (2000), pp. 517-527.
  6. Eric.W.Lemmon., Jacobsen T.Richard., Equations of State for Mixtures of R-32, R-125, R-134a, R-143a, and R-152a, Journal of Physical Chemical Reference Data, 33(2004) 2, pp. 592 - 620.
  7. Jianfeng Wu., et.al., Development of a -1860C cryogenic preservation chamber based on a dual mixed-gases Joule Thomson refrigeration cycle, Applied Thermal Engineering, 36 (2012), pp. 188-192.
  8. Jianlin Yu., et.al., Application of an Ejector in Autocascade Refrigeration Cycle for the Performance Improvement, International Journal of Refrigeration, 31 (2008), pp. 279-286.
  9. Johansson,A., Lundqvist, P., A method to Estimate the Circulated Composition in Refrigeration and Heat Pump systems using Zeotropic Refrigerant Mixtures, International Journal of Refrigeration, 24 (2001), pp. 798 - 808.
  10. Kai Du., et.al., A Study on the Cycle Characteristics of an Auto-Cascade Refrigeration System, Experimental Thermal and Fluid Science, 33 (2009), pp. 240-245.
  11. Lecompte, S., et al., Exergy analysis of Zeotropic mixtures as working fluids in Organic Rankine Cycles, Energy Conversion and Management. (2014)Article in Press.
  12. Sivakumar, M., et al., Exergy and Energy analysis of Three Stage Auto Refrigerating Cascade System using Zeotropic Mixture for Sustainable Development, Energy Conservation and Management. 83(c) (2014), pp. pp. 589-596.
  13. Sivakumar, M., et al., Exergy and Performance analysis of Three Stage Auto Refrigerating Cascade (3 stage ARC) System using Zeotropic Mixture of Eco-Friendly Refrigerants, International Review of Mechanical Engineering. 8(1) (2014), pp. 124-134.
  14. Sivakumar, M., et al., Exergy and Performance analysis of Three Stage Auto Refrigerating Cascade (3 stage ARC) System using Environment Friendly Zeotropic Mixture of R290, R170 & R14, Pollution Research. 32(4) (2013), pp. 943-952.
  15. Atashafrooz, M., et al., Numerical Investigation of Entropy Generation in Laminar Forced Convection Flow over Inclined Backward and Forward facing steps IN a Duct under bleeding Condition, Thermal Science. 18 (2) (2014), pp. 479-492. (DOI: 10.2298/TSCI110531026A)
  16. Monsef, H., et al., Design and Construction of a Low Capacity Pump-Less Absorption System, Thermal Science. 18 (2) (2014), pp. 577-590. (DOI: 10.2298/TSCI120119016M)
  17. Mani, K., et al., Experimental Investigations with Eco-Friendly Refrigerants using Design Of Experiments Technique-Mathematical Modelling and Experimental Validation , Thermal Science. On Line 00 (2013), pp.114-114, (DOI: 10.2298/TSCI110805114M)
  18. Fan, X.W., et al., Theoretical Study of Heat Pump's using CO2 / Dimethylether as Refrigerant , Thermal Science. 17 (5) (2013),pp.1261-1268.(DOI: 10.2298/TSCI13051261F)