THERMAL BEHAVIOR OF PREMISES EQUIPPED WITH DIFFERENT ALVEOLAR STRUCTURES

Abstract

This paper presents a numerical study of local thermal behavior. Vertical walls are equipped with alveolar structure and/or simple glazing in East, South and West frontages. Local temperature is assumed to be variable with time or imposed at set point temperature. Results principally show that the simple glazing number has a sensitive effect on convection heat transfer and interior air temperature. They also show that the diode effect is more sensitive in winter. The effect of alveolar structure and simple glazing on the power heating in case with set point temperature is also brought out.

Dates

  • Submission Date2013-02-04
  • Revision Date2013-12-02
  • Acceptance Date2013-12-09
  • Online Date2013-12-22

DOI Reference

10.2298/TSCI130204160L

References

  1. Guittierez D.V. Contribution to the theoretical and experimental study, the aero thermal phenomena in parallelepiped cavities with walls
  2. Seki Fokosako S., Yamagushi A., An experimental study of free convective heat transfer in a parallelogrammic enclosure, ASME Journal of Heat Transfer 105 (1983), pp. 433-439.
  3. Bairi A., Contribution to the experimental study of the natural convection in the closed cavities in parellelogrammic sections, thesis, N° 199, University of Poitiers, France, (1984).
  4. Alkhoja J.,Study of the thermal behavior unsteady of a wall of building equipped with a solar cell with slats, thesis, N° 168, University of Poitiers, France, (1982).
  5. Zugari M.R. et Vullierme J.J., Amelioration of the thermal performances of a solar cell by the use of a structure with alveolar structure, Entropy, n° 176, (1993), pp. 25-30.
  6. Vullierme J.J. et Boukadida N. - Study of structure with a diode thermal effect. Application to the realisation of a variable heat insulator. Congress I.J.T.H., Rabat-Maroc, (1985), pp. 781-789.
  7. Boukadida N. et Vullierme J.J., Experimental study of the performances of a structure with effect of thermal diode. General review of thermal, 324 (1988), pp. 645-651.
  8. N. Boukadida ,S. Ben Amor, R. Fathallah and L. Guedri, Contribution to the study of heat transfer in a room with a structure variable insulation. General review of Renewable Energy CISM'08 Oum El Bouaghi (2008) pp. 79 - 88
  9. M. Boukendil, A. Abdelbaki, Z. Numerical study of heat transfer in a coupled alveolar wall subjected to a sinusoidal excitation, Journal of Theory and Applied Mechanics 2, 4, (2011), pp. 337-346