TURBULENCE AND PRESSURE DROP BEHAVIORS AROUND SEMICIRCULAR RIBS IN A RECTANGULAR CHANNEL

Abstract

The article represents an experimental investigation on friction and turbulent flow characteristics of free airflow through a rectangular duct fitted with semicircular ribs of uniform height (e = 3.5 mm) on one principle wall. The aspect ratio of the rectangular duct was AR= 5 where the duct height (H) was 30 mm. Four different rib pitches (P) of 28 mm, 35 mm, 42 mm and 49 mm were examined with constant rib height to hydraulic diameter ratio (e/Dh= 0.07) and constant rib height to channel height ratio (e/H = 0.116). The experimental results show some significant effects of pressure drop as well as turbulent characteristics at various configurations among different numbers of rib arrangements varying Reynolds number in the range of 15000 to 30000. Experimental results have been compared with numerical analysis and it can be seen a good agreement. The result explains the phenomena elaborately between two periodic ribs and enables to optimize the rib pitch ratio in terms of turbulence kinetic energy for maximum heat transfer.

Dates

  • Submission Date2011-10-22
  • Revision Date2012-07-01
  • Acceptance Date2012-07-11

DOI Reference

10.2298/TSCI111022142N

References

  1. Webb, R. L., Eckert, E. R. G., and Goldstein. R. J., Heat Transfer and Friction in Tubes with Repeated-Rib Roughness, International Journal of Heat and Mass Transfer, 14 (1971) , pp. 601-617
  2. Hanjalic, K., Launder, B.E., Fully Developed Asymmetric Flow in a Plane Chanel, Journal of Fluid Mechanics, 51(1972), pp. 301- 335
  3. G. Tanda, Heat transfer in rectangular channels transverse and V-shaped broken ribs, International Journal of Heat and Mass Transfer, 47(2004) , pp. 229-243
  4. J. C. Han, Y. M. Zhang, High performance heat transfer duct with parallel and V-shaped broken rib, International Journal of heat and mass transfer, 35 (1992), pp. 513-523
  5. P.R. Chandra, C.R. Alexander, J.C. Han, Heat transfer and friction behavior in rectangular channel with varying number of ribbed walls, International Journal of Heat and Mass Transfer, 46 (2003) , pp. 481-495
  6. M. Huh, Y.H. Liu, J.C. Han, S. Chopra, Effect of Rib Spacing on Heat Transfer in a Two-pass Rectangular Channel (AR = 1:4) with a Sharp Entrance at High Rotation Numbers, ASME Paper no. GT2008-50311, 2008
  7. Khudheyer S. MUSHATET, Simulation of turbulent flow and heat transfer over a backward -facing step with ribs turbulators, Thermal Science, 15 (2011), 1, pp. 245-255
  8. Hwang, J. J., Heat transfer-friction characteristic comparison in rectangular ducts with slit and solid ribs mounted on the wall, ASME J. Heat Transfer, 120 (1998), 3, Pp. 709-716
  9. Wilcox, D. C., Turbulent modeling for CFD, DCW Inc, 1993
  10. Menter, F. R., Zonal two-equation k-ω turbulence model for aerodynamic flow, AIAA Paper, pp. 1993-2906, 1993
  11. Durbin, P. A., A Reynolds stress model for near-wall turbulence, J. Fluid Mechanics, 249 (1993), pp. 456-498,
  12. Vukman BAKI, Martin SCHMID and Branislav STANKOVI, Experimental investigation of turbulent structures of flow around a sphere, Thermal Science, 10 (2006), 2, pp. 97-112
  13. Fluent 6.3 user's guide. Fluent Inc; 2003.
  14. Frank P. Incropera, David P. DeWitt, Introduction to Heat Transfer, Second Edition, Page no. 408
  15. Kline, S. J. and McClintock, F. A., Describing Uncertainties on Single Sample Experiments, Mechanical Engineering, 57 (1953)
Volume 18, Issue 2, Pages419 -430