BENCHMARKING OF THE SW80 POLYCRYSTALLINE SILICON MODULES USING THE SUN AS SOURCE OF LIGHT

Abstract

Benchmarking of modules is necessary as it helps to note any changes on the operation of the modules when in operation outdoors. The equipment needed to do this has been found to be very expensive hence the need of cheaper methods. This paper tries to show how this can be achieved using outdoor conditions and an I/V measuring instrument PVPM1000. SW80 photovoltaic modules were tested using outdoor conditions. The current and voltage measurements were taken at solar noon and converted to the standard test conditions (STC, 1000 Wm-2 AM 1.5 and 25°C). These normalized values were in turn taken as bench mark values of the modules. Future measurements can then be taken at solar noon and compared to benchmark values; any variations in performance can then be noted. The variations on benchmark values as compared to the manufacturer STC values for SW80 type module were noted. The measurements were carried out under typical South Africa meteorological conditions.

Dates

  • Submission Date2011-08-15
  • Revision Date2012-04-20
  • Acceptance Date2012-05-04

DOI Reference

10.2298/TSCI110815088M

References

  1. 1600W Solar Simulator, search.newport.com/?q=*&x2=sku&q2=92190
  2. SW80 performance under standard conditions, www.solarworld-usa.com/system-designers/~/media/Global/PDFs/Sunmodule-SW-80-90-poly-RIA.pdf
  3. Koyanagi. J and Kurokawa. K. A fundamental experiment of solar cell's I/V characteristics measurement using LED solar simulator. Renewable Energy Proceedings ,2006.
  4. Jacobson, A., Duke, R.,Kamen, D.M., Hankins, M. Field Performance Measurements of Amorphous Silicon Photovoltaic Modules in Kenya. The American Solar Energy Society (ASES) Proceedings, Madison, Wisconsin, USA, June 16-21, 2000.
  5. Eikelboom .J.A and Jansen. M.A. Characterisation of PV Modules of New Generations. ECN-C-00-067, 2000.
  6. Antony. F, Durschner. C., Remmers. K-H (2006). Photovoltaics for professionals, Solar electric systems marketing, design and installation. Solarpraxis AG. Berlin, 2006.
  7. Skoplaki E. and Palyvos. J.A (2009). On the temperature dependence of photovoltaic module electrical performance: A review of efficiency/power correlations. Solar Energy, 83 (2009) pp 614-624
  8. SOZ-03 Technical data, www.nes-datalogger.de/produkte_soz03.htm.
  9. PVPM technical datasheet, www.pv-engineering.de/_docs/datenblatt/pvpm-datasheet.PDF.
  10. Mismatch effects,www.pveducation.org/pvcdrom/modules/mismatch-effects.
Volume 18, Issue 12, Pages317 -322