EXPERIMENTAL INVESTIGATION ON OPTIMAL TEMPERATURE LIFT OF AN INVERTER HEAT PUMP SYSTEM

Abstract

The temperature lift directly influences the efficiency of the heat pump, meanwhile, the coefficient of performance and the heat sink temperature lift of heat pump systems are mutually exclusive parameters, i.e., the higher temperature lift leads to the lower coefficient of performance while the lower temperature lift leads to the higher coefficient of performance. To deal with the dilemma, a primary theoretical analysis is performed, and a case study of an inverter water source heat pump is carried out, which is operated under the conditions of compressor frequency of 15-85 Hz and heat sink flow rate of 120/160/180/200 kg/h, respectively. The relationships among the temperature lift, coefficient of performance and compressor power consumption are analyzed, The results show that the optimal temperature lift mainly depends on the inlet temperature of heat sink, and has little to do with the compressor frequency and water flow rate, which are of significance for the optimal operation of heat pump systems.

Dates

  • Submission Date2013-02-16
  • Revision Date2013-04-20
  • Acceptance Date2013-04-25
  • Online Date2013-12-28

DOI Reference

10.2298/TSCI1305459W

References

  1. Greening, B., Azapagic, A., Domestic Heat Pumps: Life Cycle Environmental Impacts and Potential Implications for the UK, Energy, 39 (2012), 1, pp. 205-217
  2. Rizniæ, D., Kovaèiæ, B., Water Temperature Adjustment in Spas by the Aid of Heat Pumps, Thermal Science, 16 (2012), 4, pp. 1127-1136
  3. Blarke, M. B., Lund, H., Large-Scale Heat Pumps in Sustainable Energy Systems System and Project Perspectives, Thermal Science, 11 (2007), 3, pp. 143-152
  4. Lee, H., et al., Optimization of Novel Heat Exchanger Design for the Application to Low Temperature Lift Heat Pump, Energy, 42 (2012), 1, pp. 204-212
  5. Zhang, J., et al., System Optimization and Experimental Research on Air Source Heat Pump Water Heater, Applied Thermal Engineering, 27 (2007), 5-6, pp. 1029-1035
  6. Sarkar, J., et al., Optimization of a Transcritical CO2 Heat Pump Cycle for Simultaneous Heat Source and Heating Applications, International Journal of Refrigeration, 27 (2004), 8, pp. 830-838
  7. Wang, F., et al., Experimental Study on an Inverter Heat Pump with HFC125 Operating near the Refrigerant Critical Point, Applied Thermal Engineering, 39 (2012), pp. 1-7
  8. Koffi, P., et al., Theoretical and Experimental Analysis of the Thermal Performance of a Solar Water Heater with Internal Exchanger Using Thermosiphon System, Energy Conversion and Management, 49 (2008), 8, pp. 2279-2290
  9. Zheng H. F., et al., Experimental Research about Solar Ejector Refrigerant Based on the Climate Condition in the Zhengzhou Region (in Chinese), Acta Energiae Solaris Sinica, 32 (2011), pp. 1169-1173
  10. Zhou, X. J., et al., The Optimal Temperature Difference of the High Temperature Heat Pump System (in Chinese), Acta Energiae Solaris Sinica, 25 (2004), pp. 394-398
  11. Huchtemann, K., Muller, D., Simulation Study on Supply Temperature Optimization in Domestic Heat Pump Systems, Building and Environment, 59 (2013), January, pp. 327-335
Volume 17, Issue 5, Pages1459 -1465