MODELING AND CONTROL OF TEMPERATURE OF HEAT-CALIBRATION WIND TUNNEL

Abstract

This paper investigates the temperature control of the heat air-flow wind tunnel for ensor temperature-calibration and heat strength experiment. Firstly, a mathematical odel was established to describe the dynamic characteristics of the fuel supplying ystem based on a variable frequency driving pump. Then, based on the lassical cascade control, an improved control law with the Smith predictive estimate nd the fuzzy proportional-integral-derivative was proposed. The simulation esult shows that the control effect of the proposed control strategy is better than he ordinary proportional-integral-derivative cascade control strategy.

Dates

  • Submission Date2012-08-16
  • Revision Date2012-09-01
  • Acceptance Date2012-09-12

DOI Reference

10.2298/TSCI1205433L

References

  1. Zhao, S., Li, L., Chen, Y., 1700 °C Hot Wind Tunnel, Aviation Metrology & Meas. Tech., 20 (2000), 4, pp. 3-6
  2. Peng, T. H., Xu, B., Yang, H. Y., Development and Research Overview on Variable Frequency Hydraulic Technology, J. of Zhejiang Univ., 38 (2004), 2, pp. 215-221
  3. Petkovic, S., Pesic, R. B., Lukic, J. K., Experimental Verification of Mathematical Model of the Heat Transfer in Exhaust System, Thermal Science, 15 (2011), 4, pp. 1035-1048
  4. Yu, H., Jia, J., Chen, G., Temperature Control of Electric Furnace Based on Fuzzy PID, Proceedings, Int. Conf. on Electronics and Optoelectronics, Shenyang, China (2011), Vol. 3, pp. 41-44
  5. Ren, D., Yao, J., Wang, Y., Dryer Surface Temperature Control System Based on Improved Self- Adaptive Fuzzy Smith Prediction Controller, Proceedings, IEEE ICIT 2005, Chengdu, China, 2005, pp. 1274-1279
Volume 16, Issue 5, Pages1433 -1436