EXPERIMENTAL DETERMINATION OF THERMAL CONDUCTIVITY OF SOIL WITH A THERMAL RESPONSE TEST

Abstract

Optimal design of a borehole heat exchanger, as the outer part of a ground source heat pump heating system, requires information on the thermal properties of the soil. Those data, the effective thermal conductivity of the soil eff and the average temperature of the soil T0, enable us to determine the necessary number and depth of boreholes. The determination of thermal conductivity of the soil in laboratory experiments does not usually coincide with the data under insitu conditions. Therefore, an in-situ method of experimental determination of these parameters, the so-called thermal response test, is presented in this paper. In addition to the description of the experimental procedure and installation overview, the paper describes methods based on theory and presents their basic limitations, through the presentation of experimental data..

Dates

  • Submission Date2010-06-27
  • Revision Date2012-05-01
  • Acceptance Date2012-05-02

DOI Reference

10.2298/TSCI100627156B

References

  1. Morgensen, P.,Fluid to duct wall heat transfer in duct system heat storage, Proceedings of the International Conference on Surface Heat Storage in Theory and Practice, Stockholm, Sweden, June 6-8, 1983, pp. 652-657.
  2. Eklöf, C., Gehlin, S., TED - a mobile equipment for thermal response tests, Ms.S. Thesis, 1996:198E, Lulea University of Technology, Sweden, 1996, 63 pp.
  3. Mattsson, N., Steinmann, G., Laloui, L., Advanced compact device for the in situ determination of geothermal characteristics of soils, Energy and Buildings, 40 (2008), 7, pp. 1344-1352.
  4. Pakud D., Matthey, B., Comparison of the thermal performance of double U-pipe borehole heat exchangers measured in situ, Energy and Buildings, 33 (2001), 5, pp. 503-507.
  5. Esen, H., Inalli, M., In-situ thermal response test for ground source heat pump system in Elazığ, Turkey, Energy and Buildings, 41 (2009), 4, pp. 395-401.
  6. Signorelli, S., Bassetti, S., Pahud, D., Kohl, T., Numerical evaluation of thermal response tests, Geothermics, 36 (2007), 2, pp. 141-166.
  7. Wang, H., Qi, C., Du, H., Gu, J., Thermal performance of borehole heat exchanger under groundwater flow: A case study from Baoding, Energy and Buildings, 14 (2009), 12, pp. 1368-1373.
  8. Bandyopadhyay, G. Gosnold, W. Mann, M., Analytical and semi-analytical solutions for short-time transient response of ground heat exchangers, Energy and Buildings, 40 (2008), 10, pp. 1816-1824.
  9. Carslaw, H.S., Jaeger, J.C., Conduction of Heat in Solids, 2nd ed., Oxford University Press, Oxford, UK, 1959.
  10. Kavanauhg S.P., Rafferty, K., Ground-source heat pumps: Design of geothermal system for commercial and institutional Buildings, American Society of Heating, Refrigeration and Air- Conditioning Engineers (ASHRAE), Atlanta, USA, 1997.
Volume 16, Issue 4, Pages1117 -1126