STUDY ON TEMPERATURE DISTRIBUTION DUE TO FREEZING AND THAWING AT THE FENGMAN CONCRETE GRAVITY DAM

Abstract

Freezing and thawing damage is one of the major problems of the Fengman concrete dam. Based on the temperature records of the dam, appropriate heat transfer boundary conditions in the dam body are suggested. A three-dimensional finite element model is used to determine annual variation of temperature field of the dam as a case study. The deterioration problem of concrete dam owing to freezing and thawing effect is investigated.

Dates

  • Submission Date2010-07-15
  • Revision Date2010-09-03
  • Acceptance Date2010-11-11

DOI Reference

10.2298/TSCI11S1027Y

References

  1. ***, ACI, Roller-Compacted Mass Concrete, ACI Manual of Concrete Practice. Part 1, ACI 207 5R-99, USA, 2004
  2. Zhu, B. F., Prediction of Water Temperature in Deep Reservoirs, Dam Engineering, 8 (1997), 1, pp. 13-25
  3. Jaafar, M. S., et al., Development of Finite Element Computer Code for Thermal Analysis of Roller Compacted Concrete Dams, Advances in Engineering Software, 38 (2007), 11-12, pp. 886-895
  4. Noorzaei, J., et al., Thermal and Stress Analysis of Kinta RCC Dam, Engineering Structures, 28 (2006), 13, pp. 1795-1802
  5. Dechaumphai, P., Lim, W., Finite Element Thermal Structural Analysis of Heated Products, Thammasat International Journal of Science and Technology, 1 (1996), 1, pp. 11-21
  6. Sergerlind, L. J., Applied Finite Element Analysis, John Wiley and Sons, New York, USA, 1984
  7. Hinton, E., Owen, D. R. J., An Introduction to Finite Element Computations, Pineridge Press Limited, UK, 1981
  8. Li, S. J., Liu, Y. X., Numerical Computation and Analysis of Fracturing Problems of Concrete Dam Owing to Freezing and Thawing, Rock and Soil Mechanic, 25 (2005), 2, pp. 189-193
Volume 15, Issue 11, Pages27 -32