CO EMISSION REDUCTION OF A HRSG DUCT BURNER

Abstract

A heat-recovery steam generator was erected after a gas-turbine with a duct burner into the district heat centre. After commissioning, the CO emissions were found to be above the acceptable level specified in the initial contract. The Department of Energy Engineering of the BME was asked for their expert contribution in solving the problem of reducing these CO emissions. This team investigated the factors that cause incomplete combustion: the flue-gas outlet of the gas-turbine has significant swirl and rotation, the diffuser in between the gas-turbine and heat-recovery steam generator is too short and has a large cone angle, the velocity of flue-gas entering the duct burner is greater than expected, and the outlet direction of the flammable mixture from the injector of the duct burner was not optimal. After reducing the flow swirl of flue-gas and modifying the nozzle of the duct burner as suggested by the Department of Energy Engineering of the BME, CO emissions have been reduced to an acceptable level. The method involves the application of CFD modeling and studying images of the flames which proved to be very informative.

Dates

  • Submission Date2010-03-31
  • Revision Date2010-04-11
  • Acceptance Date2010-09-20

DOI Reference

10.2298/TSCI1003845L

References

  1. Catalano, L. A., et al.,Thermal Design and Emissions of Duct-Burners for Combined-Cycle and Cogenerative Plants, International Journal of Environmental Technology and Management, 7 (2007), 1-2, pp. 165-177
  2. Catalano, L. A., et al., Efficient Design Optimization of Duct-Burners for Combined-Cycle and Cogenerative Plants Engineering Optimization, 38 (2006) , 7, pp. 801-820
  3. Baukal, Ch. E., Jr., Heat Transfer in Industrial Combustion, Industrial Burners Handbook (Industrial Combustion), John Zink Co. LLC, Tulsa, Okla., USA, 2003, ISBN: 9780849313868
  4. Backlund, J. C., Bergmans, S. C. G., Value-Added Applications of Supplementary Firing in Gas Turbine Based Co-Generation Plants, ABMA Industrial Boiler Systems Conference, 1997, West Henrietta, New York, USA, www.coen.com/i_html/white_suppfire.html
  5. www.rolls-royce.com/energy/energy_products/gas_turbines/rb211/index.jsp
  6. Supplementary Firing Burners,
  7. www.stork-thermeq.nl/UserFiles/file/PDF/downloads/Supplement_Burner_2007_LR.pdf
  8. Petrone, G., et al., Reacting Flows in Industrial Duct-Burners of a Heat Recovery Steam Generator, COMSOL Conference, Hannover, Germany, 2008,
  9. http://cds.comsol.com/access/dl/papers/5493/Petrone.pdf
  10. Vanoverberghe, K. P., et al., Multiflame Patterns in Swirl-Driven Partially Premixed Natural Gas Combustion, J. Eng. Gas Turbines Power, 125 (2003), 1, pp. 40-45
  11. Nasr, A. J., Lai, C. S., The Effects of Wall Inclination on an Inclined Offset Jet,
  12. www.unsw.adfa.ecu.au/~jcl/research/turbulence/jets/NasrLai.pdf
  13. Chiummo, G., et al., Parametrical Analysis on a Exhaust Gas-Methane Burner in Steady-State Conditions: a Post-Combustion Case, www.combustion.org.uk/ECM_2005/Papers/244_Mongiello.pdf
  14. Jayatunga, C., et al., Computational Aero-Acoustic Studies of an Exhaust Diffuser, ftp.rta.nato.int
Volume 14, Issue 3, Pages845 -854